Degradation of r-a

From ISMOC
Revision as of 00:54, 25 September 2017 by Areti ts (talk | contribs) (Parameters with uncertainty)
Jump to: navigation, search

The mRNA complex of scbR-scbA degrades very soon after its formation.

Go back to overview
About this image

Chemical equation

r-a\rightarrow \varnothing

Rate equation

 r= d_{mRA}\cdot[r-a]

Parameters

The parameter of this reaction is the degradation rate of the r-a complex d_{mRA}.

Name Value Units Value in previous GBL model [1] Remarks-Reference
d_{mRA} 0.35−69.3 [2] [3]  min^{-1} 0.01 s^{-1} (0.6 min^{-1})[1]

Bistability range: 0-1.24 s^{-1}

(0-74.4 min^{-1})

In a study on the properties of antisense RNA and on the effect it has on gene regulation in bacteria, Georg et al. report that the antisense RNAs resulting from overlapping or divergent promoters (i.e. isiA/IsrR sense/antisense pair in Synechocystis PCC6803) that form a complex, co-degrade almost immediately.
Georg et al. 2012[3]

This opinion is further supported by A.J. Carpousis who, in a review on gene regulation by antisense RNA and quantifies a short mRNA half-life as approximately 2 min.

A.J. Carpousis 2003[2]

Therefore we can assume that the antisense RNA in the GBL system will follow a similar pattern and will rapidly degrade. The half-life should be kept under 2 min, therefore we can explore the range of values 0.01-2 min. From the antisense RNA half-life (t_{1/2}) we calculated the degradation rate, as per d_{mRA}= \frac{ln(2)}{t_{1/2}}, which resulted in a degradation rate constant value between 0.35-69.3 min^{-1} .

Parameters with uncertainty

When deciding how to describe the uncertainty for this parameter we must take into consideration that the reported values are either calculated with approximation from experiments corresponding to different antisense RNA degradation rates of various bacteria species and are mostly a quantification of our understanding of immediate degradation. This means that there might be a difference between the actual parameter values and the ones reported in literature, although the reported values in literature suggest that the upper bound for the half-life of such a complex would not exceed 2 minutes. These facts influence the quantification of the parameter uncertainty and therefore the shape of the corresponding distribution. By assigning the appropriate weights to the parameter values and using the method described here, the appropriate probability distribution was designed. In order to keep the values as much as possible within the desired margin, the CI factor was set to be equal to one multiplicative standard deviation instead of two (i.e. percentage 68.27%).

Therefore, in order to explore the range of reported values, the mode of the log-normal distribution of the d_{mRA} is set to  4.9 min^{-1} and the confidence interval factor is set to  14.1 , which means that the range where 95.45% of the values are found is between 0.35 and 69.3 min^{-1}.

The probability distribution for the parameter, adjusted accordingly in order to reflect the above values, is the following:

DmRAu.png

The values retrieved from literature and their weights are indicated by the blue dashed lines, and the uncertainty for each value is indicated using the reported experimental error (green lines) or a default value of 10% error (orange lines).

The location and scale parameters of the distribution are:

Parameter μ σ
d_{mRA} 3.5683 1.4065

References