Difference between revisions of "Notes"

From ISMOC
Jump to: navigation, search
Line 4: Line 4:
  
 
* When we silence the Pyruvate Kinase (dividing Vmax of PYK with 2 or 4) the PEP is supposed to accumulate and PYR is supposed to deplete. In our model PYR does deplete but PEP does not accumulate. The rate laws has been verified and no mistake was found there. Therefore now the impact of other parameters on this silencing activity is being adjusted.
 
* When we silence the Pyruvate Kinase (dividing Vmax of PYK with 2 or 4) the PEP is supposed to accumulate and PYR is supposed to deplete. In our model PYR does deplete but PEP does not accumulate. The rate laws has been verified and no mistake was found there. Therefore now the impact of other parameters on this silencing activity is being adjusted.
 +
 +
* We tried to first find out which factor is the most appropriate to divide the Vmax. We found that till factor 4 the PEP accumulates and after factor 4 although PEP concentration is higher than control but it is lower than the conecntration we get by dividing with 4.
 +
 +
* We then generated 225 stead-states from control model using 300 total parameters. We used this 225 SS models to simulate steady-state for Pyruvate Kinase silenced by dividing Vmax with 4. This gives 202 SS models in PYK_Silence. We then deleted the No-steady state models of PYK_Silence from Control Data.

Revision as of 14:27, 4 August 2014

  • Two types of simulation is being run. In one type of simulation for Control and for all types of silencing new parameter distribution is generated each time. In the next type of simulation first a parameter distribution is created and with that same parameter distribution the ensemble models of control and PYK silencing is being generated.
  • When we silence the model using our sekeleton model, the PEP accumulates and PYR depletes. But when we considered the parameter distribution for other parameters it behaves differently.
  • When we silence the Pyruvate Kinase (dividing Vmax of PYK with 2 or 4) the PEP is supposed to accumulate and PYR is supposed to deplete. In our model PYR does deplete but PEP does not accumulate. The rate laws has been verified and no mistake was found there. Therefore now the impact of other parameters on this silencing activity is being adjusted.
  • We tried to first find out which factor is the most appropriate to divide the Vmax. We found that till factor 4 the PEP accumulates and after factor 4 although PEP concentration is higher than control but it is lower than the conecntration we get by dividing with 4.
  • We then generated 225 stead-states from control model using 300 total parameters. We used this 225 SS models to simulate steady-state for Pyruvate Kinase silenced by dividing Vmax with 4. This gives 202 SS models in PYK_Silence. We then deleted the No-steady state models of PYK_Silence from Control Data.